Industrial Detectors
Pylon’s Instrument Manufacturing Division offers several devices to detect radiation including radon and thoron.
600A/610A Active Cells
Pylon’s Instrument Manufacturing Division active cells are Lucas type scintillation cells. Active cells are used for grab sampling, continuous monitoring, sniffing, etc. The atmosphere or sample that contains radon and / or thoron gas is actively placed into the cell. The 600A and 610A are designed for use with the AB7 and AB6A monitors.
Pylon also offers non standard versions of these cells including variants that are designed to detect high radon and thoron activity levels.
600P Passive Cell
Pylon’s Instrument Manufacturing Division passive cells are Lucas type scintillation cells. Passive cells are primarily used for area monitoring in continuous mode. The atmosphere that contains radon and / or thoron gas passively diffuses into the cell. The 600P is designed for use with the AB7 and AB6A monitors.
Pylon also offers non standard versions of this cell including variants that are designed to detect high radon and thoron activity levels.
CPRD / CPC / 200P Passive Cells
Pylon’s Instrument Manufacturing Division passive cells are Lucas type scintillation cells. Passive cells are primarily used for area monitoring in continuous mode. The atmosphere that contains radon and / or thoron gas passively diffuses into the cell.
Pylon also offers non standard versions of these cells including variants that are designed to detect high radon and thoron activity levels. (e.g., 20,000,000 pCi.)
110A / 300A / 200A Active Cells
Pylon’s Instrument Manufacturing Division active cells are Lucas type scintillation cells. Active cells are used for grab sampling, continuous monitoring, sniffing, etc. The atmosphere or sample that contains radon and / or thoron gas is actively placed into the cell.
Pylon also offers non standard versions of these cells including variants that are designed to detect high radon and thoron activity levels. (e.g., 20,000,000 pCi.)
TEL1 Environmental Level Detector
Pylon’s Instrument Manufacturing Division offers the model TEL1 – Trace Environmental Level detector that detects trace levels of radon. This detector is normally used for monitoring outdoor or very low level environments. It may be used for grab sampling or continuous monitoring.
This detector is designed for use with the Pylon model AB-5 series of monitors and requires an external photomultiplier tube (Ext PMT) [Both sold separately] to complete the minimum required system.
WT-A / WT-B / WT-AB Wipe Test Adapter Detectors
Pylon’s Instrument Manufacturing Division offers a series of wipe test adapter detectors. These detectors allow the User to measure alpha and / or beta radiation from wipes or swipes with the Pylon model AB-5 series of monitors [Sold separately].
SA / SB / SAB Surface Detectors
Pylon’s Instrument Manufacturing Division offers a series of surface detectors. These detectors allow the User to measure alpha and / or beta radiation over a surface to find “hot spots” with the Pylon model AB-5 series of monitors.
These detectors are designed for use with the Pylon model AB-5 series of monitors and requires an external photomultiplier tube (Ext PMT) [Both sold separately] to complete the minimum required system.
AEP-47 / BEP-47 Alpha / Beta Emitting Particulate Detectors
Pylon’s Instrument Manufacturing Division offers an alpha emitting particulate detector and a beta emitting particulate detector that allow the User to measure alpha or beta radiation using the Pylon model AB-5 series of monitors [Sold separately]. The data from the AEP-47 measurements can be used to calculate the working level (WL).
503 Filter Detector
Pylon’s Instrument Manufacturing Division offers the model 503 detector. This detector allows the User to measure alpha radiation on filters with the Pylon model AB-5 series of monitors [Sold separately].
GB Gamma / Beta Detector
Pylon’s Instrument Manufacturing Division offers the model GB – Gamma / Beta Probe that detects gamma and beta radiation. It may be used for comparative measurements or continuous monitoring.
This detector is designed for use with the Pylon model AB-5 series of monitors and requires an external photomultiplier tube (Ext PMT) [Both sold separately] to complete the minimum required system.